Dynamic monitoring test on resin regeneration of condensate polishing mixed bed
|更新时间:2025-09-28
|
Dynamic monitoring test on resin regeneration of condensate polishing mixed bed
Thermal Power GenerationVol. 43, Issue 4, Pages: 49-53(2014)
作者机构:
1. 华北电力科学研究院有限责任公司
2. 大唐国际发电股份有限公司
3. 大唐国际张家口热电有限责任公司
作者简介:
基金信息:
DOI:
CLC:TM621
Published:2014
稿件说明:
移动端阅览
JIN Xuliang, LI Yongli, WANG Yinggao, et al. Dynamic monitoring test on resin regeneration of condensate polishing mixed bed[J]. Thermal power generation, 2014, 43(4): 49-53.
DOI:
JIN Xuliang, LI Yongli, WANG Yinggao, et al. Dynamic monitoring test on resin regeneration of condensate polishing mixed bed[J]. Thermal power generation, 2014, 43(4): 49-53.DOI:
Dynamic monitoring test on resin regeneration of condensate polishing mixed bed
Against the current problem that regeneration of condensate water polishing system has no reliable adjustment basis
it proposed that the orthogonal test can be performed to monitor the content variation of various impurity ions dynamically under different regeneration conditions
and then the results can be fitted to obtain the optimal condition parameter for resin regeneration.The application in polishing system of a power plant shows that
when the concentration of Na+
NH4 +and other impurity ions decreases to below 1%
the regeneration degree of the cation resin satisfies the concentration requirements of Na+in mixed bed effluent;when the content of PO4 3-
active silica and other ions reduces to lower than 5%of the highest value
the regeneration degree of the anion resin meets the concentration requirements of Cl-in mixed bed effluent.After regeneration by following the optimal parameters
the period water volume increased from 3.3×104 t to 5.6×104 t
and the water quality of polishing was improved significantly.