Extended application of carbon sorbent traps method in mercury concentration measurement in coal-fired power plants
|更新时间:2025-09-28
|
Extended application of carbon sorbent traps method in mercury concentration measurement in coal-fired power plants
Thermal Power GenerationVol. 43, Issue 6, Pages: 17-22(2014)
作者机构:
中国华能集团清洁能源技术研究院有限公司
作者简介:
基金信息:
DOI:
CLC:X831
Published:2014
稿件说明:
移动端阅览
ZHONG Li, XIAO Ping, JIANG Jianzhong, et al. Extended application of carbon sorbent traps method in mercury concentration measurement in coal-fired power plants[J]. Thermal power generation, 2014, 43(6): 17-22.
DOI:
ZHONG Li, XIAO Ping, JIANG Jianzhong, et al. Extended application of carbon sorbent traps method in mercury concentration measurement in coal-fired power plants[J]. Thermal power generation, 2014, 43(6): 17-22.DOI:
Extended application of carbon sorbent traps method in mercury concentration measurement in coal-fired power plants
The carbon sorbent traps method was used to monitor the mercury content and speciation under high-temperature and high-ash content conditions that are beyond the allowable conditions of the EPA Method 30B
to extend its application range.The results show that
when measuring the total mercury concentration in flue gas
this method can be applied to the occasions of high dust concentration(e.g.before the WFGD system)
with the error caused by dust lower than1%
if keeping the flow rate at a lower level and employing dustproof cover.But this method is not suitable to the conditions with extreme high dust content.By applying air-cooled casing and controlling the sampling gun's insert depth
the temperature of carbon traps can be kept within a suitable range.Thus
the measurement accuracy of mercury concentration before air preheater can be ensured.For the chimney inlet and other areas with low dust concentration
the proportion of Hg0 measured by the 30B method is in accordance with the Hg-CEMS after the WFGD system
while after the CFB-FGD system
the proportion of Hg0 measured by the 30B method is slightly lower than that by the Hg-CEMS method.For locations with high dust concentration
the proportion of Hg0 measured by the 30B method may be much lower than the true value.