Reason analysis for corrosion of low carbon steel in flue gas from an LNG power plant
|更新时间:2025-09-28
|
Reason analysis for corrosion of low carbon steel in flue gas from an LNG power plant
Thermal Power GenerationVol. 43, Issue 5, Pages: 108-112(2014)
作者机构:
1. 苏州热工研究院有限公司
2. 深圳能源集团东部电厂
作者简介:
基金信息:
DOI:
CLC:TG172.9
Published:2014
稿件说明:
移动端阅览
CHEN Zhongbing, LU Yishi, LIU Xiao, et al. Reason analysis for corrosion of low carbon steel in flue gas from an LNG power plant[J]. Thermal power generation, 2014, 43(5): 108-112.
DOI:
CHEN Zhongbing, LU Yishi, LIU Xiao, et al. Reason analysis for corrosion of low carbon steel in flue gas from an LNG power plant[J]. Thermal power generation, 2014, 43(5): 108-112.DOI:
Reason analysis for corrosion of low carbon steel in flue gas from an LNG power plant
Leakage occurred many times at the tail heated tubes in heat recovery steam generator(HRSG)of a power plant.Thus
much analysis were performed
such as crack morphology observation
corrosion product analysis
corrosive element measurement and tube wall temperature field FEM calculation.The results show that
the cracks have the stress corrosion cracking(SCC) characteristics and the corrosion type is intergranular fracture SCC.During a certain period of unit startup and shutdown for peaking operation
the low temperature of feed water or flue gas causes the tube outer wall temperature decreases to lower than the flue gas dew point
so the flue gas dews and the SCC solution emerges on outer wall of the tube.The CO2solution is considered as the dominant component resulting in SCC.