Anticorrosion performance of bismaleimides composite material applied in coal-fired power plant chimneys
|更新时间:2025-09-28
|
Anticorrosion performance of bismaleimides composite material applied in coal-fired power plant chimneys
Thermal Power GenerationVol. 43, Issue 4, Pages: 98-101(2014)
作者机构:
1. 中国大唐集团科技产业有限公司
2. 深圳市景江化工有限公司
作者简介:
基金信息:
DOI:
CLC:TQ515.9
Published:2014
稿件说明:
移动端阅览
WEN Zhipeng, WU Zeming, SUN Zhongxiao. Anticorrosion performance of bismaleimides composite material applied in coal-fired power plant chimneys[J]. Thermal power generation, 2014, 43(4): 98-101.
DOI:
WEN Zhipeng, WU Zeming, SUN Zhongxiao. Anticorrosion performance of bismaleimides composite material applied in coal-fired power plant chimneys[J]. Thermal power generation, 2014, 43(4): 98-101.DOI:
Anticorrosion performance of bismaleimides composite material applied in coal-fired power plant chimneys
摘要
针对目前国内众多燃煤电厂脱硫烟囱防腐效果不佳的问题
研制出双马来酰亚胺(BMI)复合材料。该材料采用改型BMI树脂与碳纤维氟橡胶增强相融合技术
具有高强度、高韧性及耐高温、抗热冲击的性能;同时采用纳米片状填料插层复合技术
形成高屏蔽阻隔效果
可以满足火电厂烟气脱硫烟囱的防腐需要。
Abstract
According to the poor anti-corrosion effect of FGD chimney in most domestic coal-fired power stations in recent years
the bismaleimides(BMI)composite material has been developed
which has high strengthen
well toughness and good thermal-shock resistance.Besides the fusion technology of improved BMI resin and carbon fiber fluorine rubber
the BMI material also applies the nano plate-like filling intercalation compounding technology
which forms high shielding and obstructing property.Therefore
this BMI material can fully satisfy the needs of domestic chimney anti-corrosion.