Diameter design for main drainage pipe in high pressure steam air preheater of a waste incineration power plant
|更新时间:2025-09-28
|
Diameter design for main drainage pipe in high pressure steam air preheater of a waste incineration power plant
Thermal Power GenerationVol. 43, Issue 3, Pages: 107-109(2014)
作者机构:
中国恩菲工程技术有限公司
作者简介:
基金信息:
DOI:
CLC:TM619
Published:2014
稿件说明:
移动端阅览
CHEN Songxuan, CHEN Nanxiang, ZHANG Wenkun, et al. Diameter design for main drainage pipe in high pressure steam air preheater of a waste incineration power plant[J]. Thermal power generation, 2014, 43(3): 107-109.
DOI:
CHEN Songxuan, CHEN Nanxiang, ZHANG Wenkun, et al. Diameter design for main drainage pipe in high pressure steam air preheater of a waste incineration power plant[J]. Thermal power generation, 2014, 43(3): 107-109.DOI:
Diameter design for main drainage pipe in high pressure steam air preheater of a waste incineration power plant
volume expansion and pressure drop will occur during the high pressure drainage water flowing inside pipelines of a waste incineration power plant.On the basis of experiences on waste to power
the authors pointed out the Darcy's equation was not fit for calculating the allowed specific pressure drop in the high pressure drainage water pipeline.Thus
they proposed that
during the diameter design for the main drainage pipe
two conditions should be simultaneously controlled.One was the ratio of the pipeline flow volume to the evaporation expansion volume should be within the range from 1to 1.5
the other was the flow rate of wet steam in the main pipe should be within the range from 15m/s to 25m/s.