Discrimination of different forms of chlorides in phosphate ester fire-resistant fluids and their influences on fluid performance
|更新时间:2025-09-28
|
Discrimination of different forms of chlorides in phosphate ester fire-resistant fluids and their influences on fluid performance
Thermal Power GenerationVol. 43, Issue 6, Pages: 55-59(2014)
作者机构:
国网浙江省电力公司电力科学研究院
作者简介:
基金信息:
DOI:
CLC:TM621.8
Published:2014
稿件说明:
移动端阅览
MING Julan, TIAN Gangqiang, ZHOU Feimei, et al. Discrimination of different forms of chlorides in phosphate ester fire-resistant fluids and their influences on fluid performance[J]. Thermal power generation, 2014, 43(6): 55-59.
DOI:
MING Julan, TIAN Gangqiang, ZHOU Feimei, et al. Discrimination of different forms of chlorides in phosphate ester fire-resistant fluids and their influences on fluid performance[J]. Thermal power generation, 2014, 43(6): 55-59.DOI:
Discrimination of different forms of chlorides in phosphate ester fire-resistant fluids and their influences on fluid performance
The determination methods of hydrolysable chlorides(HCs)and un-hydrolysable chlorides(UHCs)in phosphate ester fire-resistant fluids were presented.Moreover
the influence of HC and UHC on fluid performance were analyzed.The results indicate that the method of water extraction-ionic chromatogram(WE-IC)can be used for HCs determination
of which the average recovery was 98.37% and the relative standard deviation(RSD)was 1.09%.The solubility of hydrolysable chlorides in fire-resistant fluid was lower than 5mg/kg
contributing little to the total chlorine content.The UHCs had little influences on fluid performance.As long as the performance indexes
such as hydrolytic stability and direct current resistivity are under control
the phosphate ester fire-resistant fluid can still be in serves