Numerical simulation on low NOx combustion system retrofitting for a 600MW unit boiler
|更新时间:2025-09-28
|
Numerical simulation on low NOx combustion system retrofitting for a 600MW unit boiler
Thermal Power GenerationVol. 43, Issue 8, Pages: 120-124(2014)
作者机构:
1. 神华国华电力公司
2. 内蒙古国华呼仑贝尔发电有限公司
作者简介:
基金信息:
DOI:
CLC:TK223.2
Published:2014
稿件说明:
移动端阅览
WANG Yingcong, LU Kun. Numerical simulation on low NOx combustion system retrofitting for a 600MW unit boiler[J]. Thermal power generation, 2014, 43(8): 120-124.
DOI:
WANG Yingcong, LU Kun. Numerical simulation on low NOx combustion system retrofitting for a 600MW unit boiler[J]. Thermal power generation, 2014, 43(8): 120-124.DOI:
Numerical simulation on low NOx combustion system retrofitting for a 600MW unit boiler
To solve the problem of high NOxemission in a 600 MW subcritical controlled circulation boiler
compound air staging technology retrofit schemes with vertical air staging along furnace height direction and horizontal air staging in main combustion zone were proposed.The numerical simulation software Fluent was employed to investigate the influence of SOFA elevation and spacing on combustion temperature
CO concentration and NOxemission.The results show that
the simulation results can well reflect the actual combustion situation.In the scheme of air staging combustion
the temperature of primary combustion zone reduced
while that at the furnace outlet increased.The CO concentration at the furnace outlet rose and the NOxemission decreased significantly.The results of comprehensive comparison and analysis on the NOxemission
furnace outlet gas temperature and boiler efficiency proved the C2 condition was be the optimum arrangement.