Emission characteristics of PM2.5 from flue gas desulfurated by limestone-gypsum method
Emission characteristics of PM2.5from flue gas in simulated system and actual coal-fired power plant equipped with limestone-gypsum desulfurization system were investigated.The results show that the number concentration distribution of PM10 in raw flue gas
determined by ELPI in simulation system
presented a unimodal distribution while that in actual power plant was bimodal.Most of the fine particles were in submicron size range
with an irregular structure of sphere and a main composition of water-insoluble salic minerals.After desulfurization
the number peak particle size had moved from 0.07μm to 0.15μm
and the number of coarse particles decreased slightly.However
the particles sizing from in 0.1μm to 0.5μm increased instead
indicating the WFGD had a lower efficiency in removing the fine particles.Furthermore
a few crystalline particles in micron size appeared