An experimental system for thermal performance test of large-scale air-cooling towers
|更新时间:2025-09-28
|
An experimental system for thermal performance test of large-scale air-cooling towers
Thermal Power GenerationVol. 43, Issue 11, Pages: 79-82(2014)
作者机构:
华北电力大学电站设备状态监测与控制教育部重点实验室
作者简介:
基金信息:
DOI:
CLC:TK172
Published:2014
稿件说明:
移动端阅览
XI Xinming, GUO Yonghong, DU Xiaoze, et al. An experimental system for thermal performance test of large-scale air-cooling towers[J]. Thermal power generation, 2014, 43(11): 79-82.
DOI:
XI Xinming, GUO Yonghong, DU Xiaoze, et al. An experimental system for thermal performance test of large-scale air-cooling towers[J]. Thermal power generation, 2014, 43(11): 79-82.DOI:
An experimental system for thermal performance test of large-scale air-cooling towers
On the basis of a 600 MW indirect air cooling unit
an experimental system for large-scale air-cooing tower was designed by means of the similarity principles
with a proportion of 1to 30.This system consists of modeling air cooling tower
air cooling modeling radiator
heat load power control system and data collection system.During the experiment
the heat load can be regulated by the control system
according to the parameters' value and experimental purpose.The calculation shows the measurement error of heat transfer coefficient of this experimental system is less than 20%.Through this system
the flow and heat transfer characteristics at inside and outside of the dry-cooling tower under various environmental conditions can be measured.Moreover
the correlations of flow and heat transfer of air-cooled heat exchanger and the off-design performance of the indirect dry cooling system can be obtained.The hot plume recirculation flows
anti-freezing in winter and the thermo-hydraulic performances for stack and tower integration design can be investigated using this experimental system.The design principle
basic parameters and measuring errors were analyzed.
Configuration optimization for a large-scale dry-cooling tower
Research progress of heat transfer enhancement in two-phase closed gravity heat pipe
Effects of attack angle and endwall slippage on flow and heat transfer of blade squealer tip
MEASUREMENT OF HYDROGEN CONDUCTIVITY IN WATERSTEAM SYSTEM OF THERMAL POWERGENERATING UNITS
MEASUREMENT AND ANALYSIS OF HEAT TRANSFER COEFFICIENT FOR PLATEN HEATING SURFACE IN CFB BOILERS
Related Author
YANG Yongping
YANG Lijun
DU Xiaoze
WEI Huimin
YANG Rui
WU Zhong
WANG Lipeng
LI Chunxiao
Related Institution
Key Laboratory of Condition Monitoring and Control for Power Plant Equipment, North China Electric Power University, Ministry of Education
School of Energy and Power Engineering, Shenyang University of Chemical Technology
Liaoning Key Lab of Advanced Measurement and Test Technique for Aviation Propulsion System, Faculty of Aerospace Engineering, Shenyang Aerospace University