Double-mode control strategy of superheated steam temperature for ultra-supercritical power units
|更新时间:2025-09-28
|
Double-mode control strategy of superheated steam temperature for ultra-supercritical power units
Thermal Power GenerationVol. 43, Issue 8, Pages: 71-74(2014)
作者机构:
1. 太原理工大学信息工程学院
2. 内蒙古电力科学研究院
作者简介:
基金信息:
DOI:
CLC:TK323;TM621
Published:2014
稿件说明:
移动端阅览
LU Yanjie, NIU Yuguang, ZHANG Qian. Double-mode control strategy of superheated steam temperature for ultra-supercritical power units[J]. Thermal power generation, 2014, 43(8): 71-74.
DOI:
LU Yanjie, NIU Yuguang, ZHANG Qian. Double-mode control strategy of superheated steam temperature for ultra-supercritical power units[J]. Thermal power generation, 2014, 43(8): 71-74.DOI:
Double-mode control strategy of superheated steam temperature for ultra-supercritical power units
摘要
由于过热蒸汽温度具有非线性、大时变、大迟延等特点
传统PID串级控制在工况变化时难以取得较好的控制效果。对此
将内模控制与模糊控制相结合
并引入多模型理念
提出了基于内模原理和模糊控制的二模态控制方案
对国电布连电厂超超临界660MW机组直流锅炉过热蒸汽温度串级控制系统进行改进
将改进后的控制策略用于EDPF-NT DCS。结果表明
改进后的控制系统较传统过热蒸汽温度PID串级控制系统具有更强的负荷适应能力和鲁棒性
在机组负荷变化较大时仍具有良好的控制品质。
Abstract
Due to such characteristics as nonlinearity
large time-varying and large delay of the superheated steam temperature
the conventional PID cascade control can no obtain satisfactory effect.In this regard
by combining the internal model control with the fuzzy control and introducing the concept of multi-model
the two-mode control scheme was proposed
on the basis of the internal model principle and fuzzy control.Moreover
the superheated steam temperature cascade control system in once-through boiler of an ultra-supercritical 660 MW unit was optimized
and the improved control strategy was applied in EDPF-NT DCS.The results show that
compared with the conventional PID cascade control system
the improved control system has stronger adaptability and robustness of the load
and it still has good control quality when the unit load greatly changes.