Numerical optimization design for low NOx combustion system of a Foster-Wheeler type down fired boiler
|更新时间:2025-09-28
|
Numerical optimization design for low NOx combustion system of a Foster-Wheeler type down fired boiler
Thermal Power GenerationVol. 43, Issue 12, Pages: 31-37(2014)
作者机构:
西安热工研究院有限公司
作者简介:
基金信息:
DOI:
CLC:TK223.2
Published:2014
稿件说明:
移动端阅览
LI Hongzhi, YAN Wanjun, ZHAO Zhiping, et al. Numerical optimization design for low NOx combustion system of a Foster-Wheeler type down fired boiler[J]. Thermal power generation, 2014, 43(12): 31-37.
DOI:
LI Hongzhi, YAN Wanjun, ZHAO Zhiping, et al. Numerical optimization design for low NOx combustion system of a Foster-Wheeler type down fired boiler[J]. Thermal power generation, 2014, 43(12): 31-37.DOI:
Numerical optimization design for low NOx combustion system of a Foster-Wheeler type down fired boiler
摘要
针对FW型W火焰锅炉燃尽性差、飞灰含碳量高、NOx排放浓度高等问题
提出了高效低氮燃烧系统改造方案
并以某FW型W火焰锅炉为模型进行了数值模拟计算
对比分析了低氮燃烧系统改造前后炉膛空气动力场、温度场、煤粉颗粒轨迹及NOx分布特点。结果表明
改造后NOx排放浓度由1 158.9mg/m3降至793.4mg/m3
炉膛出口烟气温度由1 126℃降至1 075℃
炉膛温度分布均匀
减温水流量和蒸汽温度偏差减小
提高了锅炉燃烧的稳定性和安全性。
Abstract
To solve such problems as poor burnout characteristics
high fly ash content and high NOxemission concentration occurred in FW type down fired boilers
a high efficient transformation scheme for low NOxcombustion system was proposed.Moreover
an FW type W-shaped flame boiler was taken as the model to carry out the simulation.The aerodynamic field
temperature field
coal particles trajectory and NOxconcentration distribution before and after the low NOx optimization retrofitting were comparatively analyzed.The results show that
after the transformation
the NOxemission decreased from 1 158.9mg/m3 to 793.4mg/m3
the furnace outlet gas temperature dropped from 1 126 ℃ to 1 075 ℃
the temperature field in furnace had good uniformity and the deviation of the desuperheating water quantity and the steam temperature reduced
which enhanced the stability and safety of the combustion.