Numerical simulation on low-NOx emission in a 600MW unit boiler with staged-air combustion
|更新时间:2025-09-28
|
Numerical simulation on low-NOx emission in a 600MW unit boiler with staged-air combustion
Thermal Power GenerationVol. 43, Issue 10, Pages: 79-84(2014)
作者机构:
1. 北京巴布科克.威尔科克斯有限公司
2. 华北电力大学电站设备状态监测与控制教育部重点实验室
作者简介:
基金信息:
DOI:
CLC:TK221
Published:2014
稿件说明:
移动端阅览
YANG Jiao, SUN Baomin. Numerical simulation on low-NOx emission in a 600MW unit boiler with staged-air combustion[J]. Thermal power generation, 2014, 43(10): 79-84.
DOI:
YANG Jiao, SUN Baomin. Numerical simulation on low-NOx emission in a 600MW unit boiler with staged-air combustion[J]. Thermal power generation, 2014, 43(10): 79-84.DOI:
Numerical simulation on low-NOx emission in a 600MW unit boiler with staged-air combustion
The NOxemitted from a 600 MW unit tangentially fired boiler at full load had a high concentration of about 400mg/Nm3
which can't meet the national requirements of NOxemissions for the utility boilers.Thus
the method combining the advanced hybrid air-staged low-NOxcombustion technology with furnace arrangement was applied to reduce the NOxemission.In addition
by the Fluent software and the realizable k-εmodel
comparison of NOxemissions and pulverized coal combustion process between the original burner structure and the being improved ones was conducted.The flue gas temperature field
velocity field and concentration distribution of CO
O2 and NOxaround the burner area were obtained.The results show that the staged-air combustion can reduce NOx emissions obviously and make the furnace temperature field
velocity field
CO and O2 concentration change correspondingly.The calculation error between the numerical simulation results and the experimental data was less than 5%
indicating the numerical simulation can predict the NOxformation and emission accurately
which provides some theoretical basis for the burners design and operation.