Experimental study on fan mill type selection in large lignite-fired power plants
|更新时间:2025-09-28
|
Experimental study on fan mill type selection in large lignite-fired power plants
Thermal Power GenerationVol. 43, Issue 12, Pages: 95-98(2014)
作者机构:
1. 内蒙古上都发电有限责任公司
2. 西安热工研究院有限公司
作者简介:
基金信息:
DOI:
CLC:TK223.25
Published:2014
稿件说明:
移动端阅览
LU Wengong, YANG Zhongcan, ZHANG Anguo. Experimental study on fan mill type selection in large lignite-fired power plants[J]. Thermal power generation, 2014, 43(12): 95-98.
DOI:
LU Wengong, YANG Zhongcan, ZHANG Anguo. Experimental study on fan mill type selection in large lignite-fired power plants[J]. Thermal power generation, 2014, 43(12): 95-98.DOI:
Experimental study on fan mill type selection in large lignite-fired power plants
On the basis of the test research on Shengli lignite coal grinding and calculation about large fan mill type-selection
the method of fan mill type-selection was proposed for lignite with low calorific value
low grindability
high moisture and used in high altitude conditions.It suggested the FM410.1300 fan mill be adopted and configured in 6+2mode.When the ventilation volume of a single fan mill satisfies the requirements of coal dryness in BMCR load condition
the air coal ratio is 1.54.Furthermore
according to such parameters as coal fineness R90
pulverizing unit coal consumption
ventilation and booster pressure picked up in the commissioning curves of S02 mill
the corrected booster pressure of the FM410.1 300 fan mill is 1 594 Pa.The pipeline resistance is suggested to be matched with the corresponding booster pressure.Fan mill type selection calculation for small S02 mill and the field MB3600/1000/490 large scale fan mill was conducted respectively.The obtained booster pressure agrees well with each other
indicating using the S02 fan mill to select the key parameters is reliable.