Improved TOPSIS based reliability evaluation for thermal power units
|更新时间:2025-09-28
|
Improved TOPSIS based reliability evaluation for thermal power units
Thermal Power GenerationVol. 44, Issue 5, Pages: 1-6(2015)
作者机构:
1. 华北电力大学新能源电力系统国家重点实验室
2. 华北电力大学控制与计算机工程学院
作者简介:
基金信息:
DOI:
CLC:TM621
Published:2015
稿件说明:
移动端阅览
LIU Changliang, LIU Mengqiong. Improved TOPSIS based reliability evaluation for thermal power units[J]. Thermal power generation, 2015, 44(5): 1-6.
DOI:
LIU Changliang, LIU Mengqiong. Improved TOPSIS based reliability evaluation for thermal power units[J]. Thermal power generation, 2015, 44(5): 1-6.DOI:
Improved TOPSIS based reliability evaluation for thermal power units
To ensure the security and stable operation of the whole power system
a comprehensive evaluation of reliability of thermal power generating units for 11 power plants nationwide was carried out
combining with improvements of the conventional TOPSIS method in weight and distance.On the basis of the unit operating data in the first half of 2012 published by the ITU
the improved Eigenvector method and information entropy method were adopted to acquire and integrate the objective and subjective weights.After that
the reliability of units in these power plants was evaluated and ranked by adopting Minkowski distance as a substitution for the Euclid distance in the conventional TOPSIS method.The results show the improved TOPSIS method is a comprehensive and effective evaluation method for the power plants' operational reliability
which can provide references for the safe and stable operation of the electric power systems.