Performance calculation of a coal-fired power station combined calcium carbide multi-generation system
|更新时间:2025-09-28
|
Performance calculation of a coal-fired power station combined calcium carbide multi-generation system
Thermal Power GenerationVol. 44, Issue 2, Pages: 8-12(2015)
作者机构:
1. 华北电力大学教育部电站设备状态监测与控制重点实验室
2. 山西国际能源集团有限公司
作者简介:
基金信息:
DOI:
CLC:TM621
Published:2015
稿件说明:
移动端阅览
LU Yongyu, YAN Weiping, JIANG Ping, et al. Performance calculation of a coal-fired power station combined calcium carbide multi-generation system[J]. Thermal power generation, 2015, 44(2): 8-12.
DOI:
LU Yongyu, YAN Weiping, JIANG Ping, et al. Performance calculation of a coal-fired power station combined calcium carbide multi-generation system[J]. Thermal power generation, 2015, 44(2): 8-12.DOI:
Performance calculation of a coal-fired power station combined calcium carbide multi-generation system
The conventional coal-based power and chemicals multi-generation are all based on coal gasification.The proposed coal-fired power station combined calcium carbide multi-generation system has simple processes and high efficient of waste heat recovery
which integrates the oxygen-fuel method based calcium carbide reactor system with the boiler combustion system.By taking a supercritical 350 MW unit coal-fired unit combined with a 0.3 Mt/a calcium carbide production system as the example
the relative energy saving ratio
cost of co-production and CO2 emission per ten thousand yuan output value were used as three indicators to evaluate the system from energy
economy and environment aspects
respectively.The results show that
comparing with the stand alone system of both power generation and calcium carbide production
the relative energy saving ratio of the proposed multi-generation system is 18.52%.The calcium carbide cost is 685yuan/t and the power supply cost is 0.32yuan/(kW·h)
both of them are lower than the calcium carbide's price and network price in Shanxi province.The CO2 emission per ten thousand yuan output value is 19.79 t
which is 17.74%lower than that of the conventional coal-fired power unit.In conclusion
the multi-generation has prominent energy utilization