Economic analysis of corrosion inhibition by increasing wall temperature of low pressure economizers
|更新时间:2025-09-28
|
Economic analysis of corrosion inhibition by increasing wall temperature of low pressure economizers
Thermal Power GenerationVol. 44, Issue 5, Pages: 55-58(2015)
作者机构:
华北电力大学教育部电站设备状态监测与控制重点实验室
作者简介:
基金信息:
DOI:
CLC:TK223.33
Published:2015
稿件说明:
移动端阅览
XU Jiaqing, YAN Weiping, HE Dong. Economic analysis of corrosion inhibition by increasing wall temperature of low pressure economizers[J]. Thermal power generation, 2015, 44(5): 55-58.
DOI:
XU Jiaqing, YAN Weiping, HE Dong. Economic analysis of corrosion inhibition by increasing wall temperature of low pressure economizers[J]. Thermal power generation, 2015, 44(5): 55-58.DOI:
Economic analysis of corrosion inhibition by increasing wall temperature of low pressure economizers
摘要
加装低压省煤器是降低电站锅炉排烟温度的有效途径
但会造成受热面腐蚀。对此
提出在低压省煤器低温管段内壁铺设低导热系数涂层以提高壁温
从而有效减缓低温腐蚀。以1 000 MW机组为例
计算分析了不同涂层厚度对受热面壁温和传热系数的影响。结果表明
与光管换热器相比
在维持换热器吸热量不变的条件下
采用在低压省煤器受热面低温段内表面铺设厚度为0.2mm的低导热系数涂层的方案
可使总换热系数下降9.1%
传热温差增加33.3%
减小受热面面积13.0%
降低烟气阻力70Pa
经济效益显著。
Abstract
Adding low pressure economizer is an effective way to reduce the exhaust flue gas temperature of boiler in a power plant
but it would result in low temperature corrosion.Increasing wall temperature of the low pressure economizer can inhibit the low temperature corrosion effectively.A scheme of laying coating with low thermal conductivity on the inner wall of the low pressure economizer in low temperature duct was put forward.Taking a 1 000 MW unit as the example
the influence of coating thickness on the wall temperature and heat transfer coefficient of the heating surface was analyzed.The results show that
laying low heat transfer coefficient coating with thickness of 0.2 mm on low temperature inner surface can decrease the total heat transfer coefficient of the low pressure economizer by 9.1%
increase the heat transfer temperature difference by 33.3%
thus to save the heating surface by about 13.0%and reduce the flue gas resistance by 70 Pa.