Comprehensive treatment of end vibration in turbine generator stator
|更新时间:2025-09-28
|
Comprehensive treatment of end vibration in turbine generator stator
Thermal Power GenerationVol. 44, Issue 5, Pages: 125-128(2015)
作者机构:
1. 广东珠海金湾发电有限公司
2. 广东电网公司电力科学研究院
作者简介:
基金信息:
DOI:
CLC:TM311
Published:2015
稿件说明:
移动端阅览
YANG Qunfa, SHEN Wenhua, LIU Shi. Comprehensive treatment of end vibration in turbine generator stator[J]. Thermal power generation, 2015, 44(5): 125-128.
DOI:
YANG Qunfa, SHEN Wenhua, LIU Shi. Comprehensive treatment of end vibration in turbine generator stator[J]. Thermal power generation, 2015, 44(5): 125-128.DOI:
Comprehensive treatment of end vibration in turbine generator stator
摘要
某600 MW机组QFSN-600-2型发电机由于定子绕组端部振动大
导致水电接头脱焊引起短路接地故障。通过振动测试分析
判断该振动源于50 Hz转子机械振动通过轴承、基座传递到定子绕组端部
传递过程由于结构共振导致振动超标。对此
采取改变定子绕组端部刚度、降低激振力及加装阻尼装置等措施
将定子绕组的端部振动最大值控制在150μm以内。
Abstract
Due to large vibration of stator end winding
the stator ground protection faults occurred twice in QFSN-600-2 600 MW generator in a 600 MW unit.Vibration tests show that
the mechanical vibration with frequency of 50 Hz transmitted from the bearing
base to the stator end winding
during this process the structural resonance caused excess vibration.Thus
a series of measures were taken to control the maximum value of turbine generator stator end winding vibration to a safe level
including changing the stator winding end stiffness
reducing the excited forces and installing damping devices.After these measures were taken