Thermodynamic characteristics of a 200MW unit with high back pressure circulating water heating
|更新时间:2025-09-28
|
Thermodynamic characteristics of a 200MW unit with high back pressure circulating water heating
Thermal Power GenerationVol. 44, Issue 4, Pages: 17-21(2015)
作者机构:
西安热工研究院有限公司
作者简介:
基金信息:
DOI:
CLC:TM621
Published:2015
稿件说明:
移动端阅览
JIANG Hao, HUANG Jiasi, WANG Hao. Thermodynamic characteristics of a 200MW unit with high back pressure circulating water heating[J]. Thermal power generation, 2015, 44(4): 17-21.
DOI:
JIANG Hao, HUANG Jiasi, WANG Hao. Thermodynamic characteristics of a 200MW unit with high back pressure circulating water heating[J]. Thermal power generation, 2015, 44(4): 17-21.DOI:
Thermodynamic characteristics of a 200MW unit with high back pressure circulating water heating
After retrofitting on high back pressure circulating water heating for a 200 MW unit
thermodynamic calculation was performed.The results show that
the heat net circulating water quantity and steam extraction amount(for heat supply)has little effects unit parameters such as heat consumption rate
unit output
heat load and circulating water outlet temperature.Under each working condition
the fuel utilization coefficient can reach about 90%
implying the energy comprehensive utilization effect is great.However
the unit back pressure is greatly affected by the heat net circulating water quantity and steam extraction amount.Moreover
the unit's operation regulating flexibility got poor and the retrofitting work capacity is pretty huge.The rotor changing time must be carefully selected after the retrofitting
and the units with very small heat load are not suitable for transformation.Due to small output of the 200 MW unit's low pressure(LP)cylinder
it suggests that the LP cylinder be split to reduce the modification range and simplify the steps.