Application of gel cation resin and MR anion resin combination in condensate polishing systems
|更新时间:2025-09-28
|
Application of gel cation resin and MR anion resin combination in condensate polishing systems
Thermal Power GenerationVol. 44, Issue 5, Pages: 118-124(2015)
作者机构:
1. 上海核工程研究设计院
2. 大唐湘潭发电有限责任公司
作者简介:
基金信息:
DOI:
CLC:TM62
Published:2015
稿件说明:
移动端阅览
HE Yanhong, TAN Xinwen, ZHU Laiye, et al. Application of gel cation resin and MR anion resin combination in condensate polishing systems[J]. Thermal power generation, 2015, 44(5): 118-124.
DOI:
HE Yanhong, TAN Xinwen, ZHU Laiye, et al. Application of gel cation resin and MR anion resin combination in condensate polishing systems[J]. Thermal power generation, 2015, 44(5): 118-124.DOI:
Application of gel cation resin and MR anion resin combination in condensate polishing systems
The basic performance indexes and actual operation situations of different resin combinations were investigated
such as the treated water quality
operating cycle time and resin working capacity.The resin type selection was compared from theoretical and actual operation aspects.Theoretically
the high DVB cation resin has advantages of high working capacity
easy regeneration of large-hole anion resin and anti-fouling performance.More than three years' operation of a power plant show that
combination of gel cation resin and MR anion resin improved the treated water quality and operation period dramatically.The sodium leakage was lower than 1 μg/L
the cation conductivity was kept between 0.06μS/cm and0.07μS/cm
and the operation period was kept more than 40 days.The application experience of this resin combination can provide references for not only high efficient and stable operation of condensate water polishing systems
but also performance evaluation in condensate polishing resins.
ELEMENTARY EXPLANATION FOR IMPROVING CONDENSATE POLISHING TECHNOLOGY
Application of high crosslinked gel type cation exchange resin and porous type anion exchange resin for condensate polishing in a 1 060MW air-cooled unit
Softening experiment on ion exchange of residual Ca (II) from high salinity wastewater
DETERMINATION OF ORGANICS′ CONTENT IN POLLUTED RESINS
STUDY ON POLLUTION PROBLEM OF RESIN IN CONDENSATE SYSTEM BY USING OCTADECYLAMINE FOR BOILER SHUTDOWN CONSERVATION OF LARGE SCALE UNITS