Hydrodynamic characteristic calculation for a 600MW unit once-through tower boiler
|更新时间:2025-09-28
|
Hydrodynamic characteristic calculation for a 600MW unit once-through tower boiler
Thermal Power GenerationVol. 44, Issue 1, Pages: 25-29(2015)
作者机构:
西安交通大学动力工程多相流国家重点实验室
作者简介:
基金信息:
DOI:
CLC:TK223.31
Published:2015
稿件说明:
移动端阅览
BI Yanshuang, WANG Shaofei, SHEN Yanrong, et al. Hydrodynamic characteristic calculation for a 600MW unit once-through tower boiler[J]. Thermal power generation, 2015, 44(1): 25-29.
DOI:
BI Yanshuang, WANG Shaofei, SHEN Yanrong, et al. Hydrodynamic characteristic calculation for a 600MW unit once-through tower boiler[J]. Thermal power generation, 2015, 44(1): 25-29.DOI:
Hydrodynamic characteristic calculation for a 600MW unit once-through tower boiler
superheater and reheater overtemperature and insufficient pulverizing system capacity occurred in the 600 MW unit once-through tower boiler in Yuanbaoshan Power Plant.Thus
the water wall of this boiler was optimized.According to the structural characteristics of the water wall and the heat load distribution features in the furnace after the transformation
the water wall was divided into the flow circuit
pressure point and flow network system comprised of connected tubes.On the basis of the mass conservation equation
momentum balance equation and energy conservation equation
the mathematic models for pressure drop and outlet steam temperature of water wall tube in subcritical boiler were established.Moreover
the total pressure drop in rising system and the outlet steam temperature of the upper and lower water wall were calculated
under conditions with different unit loads.The results show that