Design and analysis of coal pulverizing system of a 1025t/h oxy-lignite fired boiler
|更新时间:2025-09-28
|
Design and analysis of coal pulverizing system of a 1025t/h oxy-lignite fired boiler
Thermal Power GenerationVol. 44, Issue 2, Pages: 106-109(2015)
作者机构:
华北电力大学能源动力与机械工程学院
作者简介:
基金信息:
DOI:
CLC:TK229.6
Published:2015
稿件说明:
移动端阅览
GAO Jianqiang, WANG Ning, WANG Yulan. Design and analysis of coal pulverizing system of a 1025t/h oxy-lignite fired boiler[J]. Thermal power generation, 2015, 44(2): 106-109.
DOI:
GAO Jianqiang, WANG Ning, WANG Yulan. Design and analysis of coal pulverizing system of a 1025t/h oxy-lignite fired boiler[J]. Thermal power generation, 2015, 44(2): 106-109.DOI:
Design and analysis of coal pulverizing system of a 1025t/h oxy-lignite fired boiler
By taking the coal pulverizing system of a 1 025t/h oxy-fuel boiler firing lignite with high moisture and low sulfur as an example
process flow of the coal pulverizing system and mill type selection were designed
using the first flue gas recirculation as the desiccant.Moreover
thermal dynamic calculation was carried out to ascertain parameters values like the coal temperature and moisture at mill outlet.The results show that
the MPS200HP-Ⅱtype mill can satisfy the requirements of coal pulverizing system in oxy-coal combustion boilers which fire high-moisture lignite.Variation of moisture in raw coal has great influence on temperature and moisture of the pulverized coal at the mill outlet.