Effect of spray gun's atomizing parameter on denitration efficiency of SNCR system in CFB boilers
|更新时间:2025-09-28
|
Effect of spray gun's atomizing parameter on denitration efficiency of SNCR system in CFB boilers
Thermal Power GenerationVol. 44, Issue 5, Pages: 45-49(2015)
作者机构:
中国计量学院计量测试工程学院
作者简介:
基金信息:
DOI:
CLC:X773
Published:2015
稿件说明:
移动端阅览
JIANG Baobao, CHI Zuohe, WANG Jinqing, et al. Effect of spray gun's atomizing parameter on denitration efficiency of SNCR system in CFB boilers[J]. Thermal power generation, 2015, 44(5): 45-49.
DOI:
JIANG Baobao, CHI Zuohe, WANG Jinqing, et al. Effect of spray gun's atomizing parameter on denitration efficiency of SNCR system in CFB boilers[J]. Thermal power generation, 2015, 44(5): 45-49.DOI:
Effect of spray gun's atomizing parameter on denitration efficiency of SNCR system in CFB boilers
摘要
还原剂喷枪是影响非选择性催化还原法(SNCR)脱硝系统效果的重要因素。为此
对1台75t/h高温分离循环流化床(CFB)锅炉在不同喷枪下进行了脱硝试验
并在实验室研究了雾化枪喷射速度和雾化粒径对SNCR脱硝效率的影响。结果表明:在锅炉满负荷时
喷枪出力80kg/h下
扇形喷枪的脱硝效率比圆锥形喷枪高9%~11%
且在氨氮比不变的情况下
脱硝效率随喷枪出力的增大均有提高;扇形喷枪喷射速度比圆锥形喷枪大2.8m/s
雾化粒径比圆锥形喷枪小9~16μm
更有利于提高脱硝效率。
Abstract
Reducing agent spraying gun is an important factor influencing denitrification efficiency of the SNCR system.Thus
denitration experiments were carried out on a 75t/h high temperature separation circulation CFB boiler
with different spray guns.Moreover
the effect of jet velocity and particle size on denitration efficiency of the SNCR system was experimentally studied in lab-scale.The engineering test results show that
under full load condition and the spray gun output of 80kg/h
the denitration efficiency of the fan gun was about 9%to 11% higher than that of the conical gun.Furthermore
with a constant ammonia nitrogen ratio
denitration efficiency of both guns increased with the gun output.The laboratory test results show that
compared with the conical gun
the fan gun's spray velocity was 2.8m/s higher and its atomized particle size was about 17μm to 28μm smaller
indicating it is more helpful to enhancing the denitration efficiency.