Structure optimization of combustion chamber in low-temperature carbonization furnace firing low-rank pulverized coal
|更新时间:2025-09-28
|
Structure optimization of combustion chamber in low-temperature carbonization furnace firing low-rank pulverized coal
Thermal Power GenerationVol. 44, Issue 8, Pages: 55-61(2015)
作者机构:
太原理工大学煤科学与技术教育部和山西省重点实验室
作者简介:
基金信息:
DOI:
CLC:TQ534
Published:2015
稿件说明:
移动端阅览
LIU Jun, ZHANG Yongfa, WANG Ying, et al. Structure optimization of combustion chamber in low-temperature carbonization furnace firing low-rank pulverized coal[J]. Thermal power generation, 2015, 44(8): 55-61.
DOI:
LIU Jun, ZHANG Yongfa, WANG Ying, et al. Structure optimization of combustion chamber in low-temperature carbonization furnace firing low-rank pulverized coal[J]. Thermal power generation, 2015, 44(8): 55-61.DOI:
Structure optimization of combustion chamber in low-temperature carbonization furnace firing low-rank pulverized coal
The temperature field distribution inside a self-developed opposing spraying style low-temperature combustion chamber in low-temperature pyrolysis oven firing low-rank coal was simulated by CFD Fluent 6.3software.Moreover
the combustion chamber's structure was also optimized.The results show that
by designing four central axisymmetric straight dampers with length of 800 mm and 500 mm and rotation angle of±30°and ±10°
the horizontal and vertical average temperature of the combustion chamber can meet the demands of lignite low-temperature pyrolysis(500℃to 650℃).In non-premixed combustion mode with excessive air coefficient of 1.25 and the sprayer diameter of 50 mm
the combustions characteristics of the combustion chamber reached the optimum condition.The excessive air coefficient
fuel premixed mode and coal feed pipe diameter can affect the temperature field distribution in the combustion chamber.The k-εturbulence model
P-1radiation model and non-premixed combustion model were appropriate for calculating the temperature field distribution for the combustion of coke oven gas and air in the low temperature combustion chamber.The simulation results basically agreed with the experimental results
the error only fluctuated from 40℃to 80℃.Test on the exhaust gas shows the emitted flue gas satisfied the industrial emission standards.