Cause analysis and countermeasures of high-temperature sulfur corrosion of water wall in an opposed firing boiler
|更新时间:2025-09-28
|
Cause analysis and countermeasures of high-temperature sulfur corrosion of water wall in an opposed firing boiler
Thermal Power GenerationVol. 44, Issue 8, Pages: 104-108(2015)
作者机构:
1. 华北电力大学能源动力与机械工程学院
2. 国网河南省电力公司电力科学研究院
作者简介:
基金信息:
DOI:
CLC:TM621.2
Published:2015
稿件说明:
移动端阅览
XU Tao, LI Min, LI Chunxi. Cause analysis and countermeasures of high-temperature sulfur corrosion of water wall in an opposed firing boiler[J]. Thermal power generation, 2015, 44(8): 104-108.
DOI:
XU Tao, LI Min, LI Chunxi. Cause analysis and countermeasures of high-temperature sulfur corrosion of water wall in an opposed firing boiler[J]. Thermal power generation, 2015, 44(8): 104-108.DOI:
Cause analysis and countermeasures of high-temperature sulfur corrosion of water wall in an opposed firing boiler
High temperature corrosion occurred on water wall of a 600 MW unit opposed firing boiler.The corrosion inspection and flue gas atmosphere test indicates that the corrosion type was high temperature sulfur corrosion and the corrosion got more serious on middle part of the side walls.The concentration of H2 Sin flue gas was very high near the side wall surface
which reached higher than 0.1%.In order to control the high temperature corrosion
a type of closing-to-wall air device on the side wall was designed.The test results show that
after the transformation
the H2 S concentration at side A and side B of the boiler reduced by 83.20% and 87.16%
respectively
and the corresponding O2 content increased by 224.5% and155.3%
respectively.Thus
the reducing atmosphere was alleviated near the water wall and the high temperature corrosion can be effectively controlled.