Flue gas determination based soft-sensing model for coal quality monitoring for utility boilers
|更新时间:2025-09-28
|
Flue gas determination based soft-sensing model for coal quality monitoring for utility boilers
Thermal Power GenerationVol. 44, Issue 7, Pages: 62-65(2015)
作者机构:
河北省电力建设调整试验所
作者简介:
基金信息:
DOI:
CLC:TM621.2
Published:2015
稿件说明:
移动端阅览
MI Cuili, GUO Jianglong, LI Xiaoguang, et al. Flue gas determination based soft-sensing model for coal quality monitoring for utility boilers[J]. Thermal power generation, 2015, 44(7): 62-65.
DOI:
MI Cuili, GUO Jianglong, LI Xiaoguang, et al. Flue gas determination based soft-sensing model for coal quality monitoring for utility boilers[J]. Thermal power generation, 2015, 44(7): 62-65.DOI:
Flue gas determination based soft-sensing model for coal quality monitoring for utility boilers
In order to solve the problem of real time inspection of coal quality for utility boilers
a calculation model for boiler efficiency was established
from aspects of positive balance and anti-balance
on the basis of mass balance theory and coal combustion chemical analysis.The relationship between coal element ingredient and flue gas ingredient was obtained.On this basis
the coal quality soft-sensing model for utility boilers was built up.Adopting the actual operation data of a power plant when the coal quality is stable
the ultimate analysis and calorific value of the coal were calculated
and the simulated results were compared with the test data.The results show that
the relative error of the ultimate analysis and net calorific value of the coal between the simulation results and test data is within ±5%.