Control system design of single row configuration scheme of main auxiliary system in a 660MW unit
|更新时间:2025-09-28
|
Control system design of single row configuration scheme of main auxiliary system in a 660MW unit
Thermal Power GenerationVol. 44, Issue 6, Pages: 121-123(2015)
作者机构:
1. 北京国电智深控制技术有限公司
2. 中国核电工程有限公司
3. 国电建投内蒙古能源有限公司
作者简介:
基金信息:
DOI:
CLC:TM621
Published:2015
稿件说明:
移动端阅览
WANG Lei, WU Zhihui, SUN Yu, et al. Control system design of single row configuration scheme of main auxiliary system in a 660MW unit[J]. Thermal power generation, 2015, 44(6): 121-123.
DOI:
WANG Lei, WU Zhihui, SUN Yu, et al. Control system design of single row configuration scheme of main auxiliary system in a 660MW unit[J]. Thermal power generation, 2015, 44(6): 121-123.DOI:
Control system design of single row configuration scheme of main auxiliary system in a 660MW unit
On the basis of analyzing the single-row configuration control characteristics of the forced draft fan
induced draft fan
primary air fan
air preheater
turbine-driven feedwater pump and booster fan in ultra-supercritical 2×660 MW units in Bulian Power Plant
several functions of the control system were designed
including the hardware system
real-time online intelligent diagnosis
boiler main protection and interlock protection for auxiliary equipments.The redundant configuration was added in thermodynamic measuring points of the auxiliary equipments.Application of this control method in the above 660 MW units show that
the monitoring function
protection function and adjusting function of the control system were stable
unit trip and boiler shutdown caused by auxiliary faults never occurred
thus the safety and stability of unit operation can be ensured.
DISCUSSION ON APPLICATION OF FCS IN THE ASSISTANT CONTROL SYSTEM OF THERMAL POWER PLANT
OPERATIONAL CHARACTORS OF BOILERS EQUIPPED FOR ULTRA-SUPERCRITICAL 660 MW UNIT AFTER COMBINING THE BOOSTER AIR FAN IN DESULPHURIZATION SYSTEM AND THE INDUCED DRAFT FAN INTO ONE
ANALYSIS AND OPTIMIZATION OF RUN BACK CONTROL STRATEGY FOR ULTRA-SUPERCRITICAL 1000 MW UNIT
COMPARISON BETWEEN TWO TYPES OF STEAM TURBINE FOR ULTRA-SUPERCRITICAL 660MW UNITS
OPTIMIZATION OF CONTROL STRATEGE FOR TEMPERATURE-REDUCING REGULATION OF LOW-PRESSRUE SHAFT SEAL ON STEAM TURBINES
Related Author
WU Zhong-sheng1
Zeng Wei-dong3
Bai Yu-feng2
Xue Xian-min1
Jin Jian2
Cai Si-long2
Ding Wei3
Ma Huan-huan3
Related Institution
Guangdong Heyuan Power Plant
Xi'an Thermal Power Research Institute Co., Ltd
Huaneng Chaohu Power Plant
Datang Xinyang Huayu Power Generation Co., Ltd
Zhejiang Electric Power Test and Research Institute