Experimental study on ash deposition and corrosion in a CFB boiler co-firing biomass with coal
|更新时间:2025-09-28
|
Experimental study on ash deposition and corrosion in a CFB boiler co-firing biomass with coal
Thermal Power GenerationVol. 44, Issue 7, Pages: 50-54(2015)
作者机构:
1. 清华大学热科学与动力工程教育部重点实验室
2. 四川白马循环流化床示范电站有限责任公司
作者简介:
基金信息:
DOI:
CLC:TK229.66;TK6
Published:2015
稿件说明:
移动端阅览
LIU Zhi, LEI Xiujian, WANG Peining, et al. Experimental study on ash deposition and corrosion in a CFB boiler co-firing biomass with coal[J]. Thermal power generation, 2015, 44(7): 50-54.
DOI:
LIU Zhi, LEI Xiujian, WANG Peining, et al. Experimental study on ash deposition and corrosion in a CFB boiler co-firing biomass with coal[J]. Thermal power generation, 2015, 44(7): 50-54.DOI:
Experimental study on ash deposition and corrosion in a CFB boiler co-firing biomass with coal
During ash decomposition and corrosion tests in a 75t/h circulating fluidized bed(CFB)boiler burning coal and biomass
the corrosion probe equipped with three kinds of metal samples was placed in front of the superheater
and the superheater tube wall temperature was simulated with a system of air cooling.Three kinds of metal deposition samples were obtained in operating mode(duration time of 24hours)with three mixing ratios of coal and biomass.The physicochemical property of the samples was analyzed by SEM-EDX.The results show that
under the testing conditions
no deposition was found at the wind side
and the deposition formed at the lee side was different for different metallic materials.No material loss or significant corrosion was detected.It is proved in this study that depositions at the lee side of the superheater were probably more serious than that at the wind side
and the co-combustion of coal and biomass containing low levels of alkali metal will not cause serious deposition or corrosion and can be applied in industrial production.