Entransy dissipation based performance analysis for solar chimney power plant system with vertical collectors
|更新时间:2025-09-28
|
Entransy dissipation based performance analysis for solar chimney power plant system with vertical collectors
Thermal Power GenerationVol. 44, Issue 9, Pages: 48-51(2015)
作者机构:
青岛科技大学机电工程学院
作者简介:
基金信息:
DOI:
CLC:TM615
Published:2015
稿件说明:
移动端阅览
ZHOU Yan, LIU Feng, WANG Li, et al. Entransy dissipation based performance analysis for solar chimney power plant system with vertical collectors[J]. Thermal power generation, 2015, 44(9): 48-51.
DOI:
ZHOU Yan, LIU Feng, WANG Li, et al. Entransy dissipation based performance analysis for solar chimney power plant system with vertical collectors[J]. Thermal power generation, 2015, 44(9): 48-51.DOI:
Entransy dissipation based performance analysis for solar chimney power plant system with vertical collectors
On the basis of the principle of entransy dissipation and the principle of minimum thermal resistance in heat transfer theory
the expression of entransy dissipation rate of the solar chimney power plant system with vertical collectors was derived and the heat transfer performance of this system was analyzed.The results show that
the structure dimensions of the chimney are the main factors affecting the performance of the solar chimney power plant system with vertical collectors.However
the height and width of the solar chimney are limited by the height and space between the windows of high buildings
thus the thickness of the solar chimney is the foremost factor to decrease the entransy dissipation of the solar power plant system.Under conditions with constant chimney height and width
the thermal resistance of entransy dissipation of the solar system reached the minimum when the solar chimney thickness was 0.959 8m
indicating the performance of the system achieved the optimum.