Numerical simulation of buoyant and diffusion rules of thermal discharge from floating nuclear power plants
|更新时间:2025-09-28
|
Numerical simulation of buoyant and diffusion rules of thermal discharge from floating nuclear power plants
Thermal Power GenerationVol. 44, Issue 10, Pages: 58-62(2015)
作者机构:
武汉第二船舶设计研究所
作者简介:
基金信息:
DOI:
CLC:X143;TM623
Published:2015
稿件说明:
移动端阅览
DAI Tianqi, YAO Shiwei, WEI Zhiguo. Numerical simulation of buoyant and diffusion rules of thermal discharge from floating nuclear power plants[J]. Thermal power generation, 2015, 44(10): 58-62.
DOI:
DAI Tianqi, YAO Shiwei, WEI Zhiguo. Numerical simulation of buoyant and diffusion rules of thermal discharge from floating nuclear power plants[J]. Thermal power generation, 2015, 44(10): 58-62.DOI:
Numerical simulation of buoyant and diffusion rules of thermal discharge from floating nuclear power plants
The waste heat emissions of thermal discharge from floating nuclear power plants may have a negative thermal effect on the environment.Investigation on the buoyant and diffusion rules of thermal discharge from floating nuclear power plants and properly controlling the discharging temperature have great significance for seat water thermal pollution prevention.This paper simplified the thermal discharge process as thermal jet in cross flow to establish the 3Dmathematic model for thermal jets floating process
on the basis of finite volume method and using the SIMPLE algorithm and Realizable k-εturbulence model.Then this model was verified by using the experimental data from reference[5].The thermal effect range and degree of environmental velocity and discharge angle on thermal discharge were investigated.The results show that
at high ambient velocities
the convection heat transfer was intense so that the heat-affected zone was influenced less by the emission angle
while at low ambient velocities
the influence of emission angle increased remarkably due to the weakness of ambient currents scouring effect.Under the same conditions
change of emission angle in vertical plane had less effect on the central temperature along stream
and it had dramatic effect when the plane was parallel to the stream.The environmental velocity had a little effect on the central temperature along the stream.