Optimization design of dehumidification structure of the last stage blade in a steam turbine
Taking the long last stage blades of steam turbine in a 1 000 MW unit as the research objects
the condensation flow and droplet deposition in the last two stages were numerically calculated by CFX software.Effects of such dehumidification structure design parameters as the slot position
slot angle
slot width and slot number on the humidification efficiency
second water droplet removal rate and stage efficiency were investigated in detail.The results show that
to ensure excellent performance for the last stage blades
like well humidification property
high stage efficiency and great stationary blade strength
the moisture removal suction slots should be located at the place higher than 60%of the relative blade high in radial direction
and in the axial position of 80.6% and 29.2% relative blade width on the pressure and suction surfaces respectively.In addition
the slot angle should be 45°and the width ought to be 1.0 mm.If not considering the hollow stationary blade's strength
the single-stage humidification slot had better comprehensive performance.With the same slot area
the double-slot humidification slot was better.When the slot width is the same