Numerical simulation on influencing factors of flow field inside a desulfurization spray tower
|更新时间:2025-09-28
|
Numerical simulation on influencing factors of flow field inside a desulfurization spray tower
Thermal Power GenerationVol. 45, Issue 2, Pages: 110-115(2016)
作者机构:
中国能源建设集团广东省电力设计研究院
作者简介:
基金信息:
DOI:
CLC:X773
Published:2016
稿件说明:
移动端阅览
FAN Xu. Numerical simulation on influencing factors of flow field inside a desulfurization spray tower[J]. Thermal power generation, 2016, 45(2): 110-115.
DOI:
FAN Xu. Numerical simulation on influencing factors of flow field inside a desulfurization spray tower[J]. Thermal power generation, 2016, 45(2): 110-115.DOI:
Numerical simulation on influencing factors of flow field inside a desulfurization spray tower
The internal flow field of a desulfurization spray tower was numerically simulated by Fluent software.Three factors affecting the flow field was investigated
such as the slurry spraying
adding a baffle at the flue gas entrance and waste heat utilization.The results show that
spraying the slurry improved the uniformity of gas flow field
eased the effect of reflux and increased the outlet gas velocity by about 10%.Installation of a baffle can help the gas flow overcome the phenomenon of sticking wall and make the gas flow more uniform.Low temperature waste heat utilization decreased the mass flux of the gas and increased the density of gas in the tower
which made the flow field distribution of gas in the tower more uniform