Failure analysis and improvement for containment spray system valve's remote actuating mechanism in a nuclear power station
更新时间:2025-09-28
    • Failure analysis and improvement for containment spray system valve's remote actuating mechanism in a nuclear power station

    • Thermal Power Generation   Vol. 45, Issue 2, Pages: 122-124(2016)
    • CLC: TM623.8
    • Published:2016

    移动端阅览

  • LI Ruyuan. Failure analysis and improvement for containment spray system valve's remote actuating mechanism in a nuclear power station[J]. Thermal power generation, 2016, 45(2): 122-124. DOI:

  •  
  •  

0

Views

82

下载量

1

CSCD

Alert me when the article has been cited
提交
Tools
Download
Export Citation
Share
Add to favorites
Add to my album

Related Articles

FAILURE ANALYSIS OF PIPE SUPPORTS & HANGERS IN SERVICE OF THERMAL POWER PLANTS
ANALYSIS OF TUBE-BURST FAILURE ON WATER-WALL IN BOILERS FOR SUBCRITICAL 300 MW UNIT
ANALYSIS OF TYPICAL METALLIC PARTS FAILURES OCCURRED ON UTILITY BOILERS AND PREVENTIVE MEASURES THEREOF
Fracture failure analysis of Ni-based bolts for ultra-supercritical units
Fracture analysis for dissimilar metal welded joints of 12Cr1MoVG/TP347H in a utility boiler

Related Author

GUO Yan-junReseac Institute for Standardization of Product Quality in Power Industry
LIU Shu-tao21.Datang Huayu Power Generation Co Ltd
ZHANG Lei2
ZHENG Fang-ping2
LIU Bing1
LONG YiHunan Provincial Electric Power Testing and Research Institute
CHEN Hongdong
LONG Huiguo

Related Institution

Electric Power Industry Product Quality Standards Research Institute
Xi'an Thermal Power Research Institute Co., Ltd
Datang Xinyang Huayu Power Generation Co., Ltd
Hunan Electric Power Company Experimental Research Institute
State Power Construction Investment Inner Mongolia Energy Co., Ltd
0