Finite element analysis of transient stress in boiler drum during hot start-up process
|更新时间:2025-09-28
|
Finite element analysis of transient stress in boiler drum during hot start-up process
Thermal Power GenerationVol. 45, Issue 4, Pages: 76-83(2016)
作者机构:
东北电力大学能源与动力工程学院
作者简介:
基金信息:
DOI:
CLC:TM621.2
Published:2016
稿件说明:
移动端阅览
LI Yong, XU Kaicheng. Finite element analysis of transient stress in boiler drum during hot start-up process[J]. Thermal power generation, 2016, 45(4): 76-83.
DOI:
LI Yong, XU Kaicheng. Finite element analysis of transient stress in boiler drum during hot start-up process[J]. Thermal power generation, 2016, 45(4): 76-83.DOI:
Finite element analysis of transient stress in boiler drum during hot start-up process
which is based on the actual boiler drum structure size
was established by pre-processor of ANSYS
to study the effects of hot start-up speed on stresses in boiler drum.Combining with the hot start-up curves given by operation rules and five hot start-up curves at different temperature rising rates
the transient stress field of the boiler drum was investigated.The results indicate that
during the hot start-up
the maximum mechanical stress intensity and the maximum total stress intensity locate at the inner joint corner of drum shell and downcomer in the longitudinal cross section.The maximum thermal stress intensity locates at the inner joint corners of drum shell and risers which are in contact with the normal water line in the horizontal cross section.As the temperature rising rate increases from 2 ℃/min to 5℃/min
the hot start-up speed has no effect on the maximum mechanical stress intensity of the most dangerous point on the boiler drum
but the maximum thermal stress intensity increases with the temperature rising rate.In the latter stage of hot start-up process
the thermal stress is not going to work.The total stress is largely driven by the mechanical stress.So the maximum total stress intensity is the same as the maximum mechanical stress intensity
and they don't change with the temperature rising rate but with the pressure in the drum.Therefore
the boiler drum can suffer a higher temperature rising rate during the hot start-up
compared with the value given by the operation rule.