A deep waste heat utilization system for utility boilers based on segmented air preheater design
|更新时间:2025-09-28
|
A deep waste heat utilization system for utility boilers based on segmented air preheater design
Thermal Power GenerationVol. 45, Issue 4, Pages: 41-47(2016)
作者机构:
华北电力大学热电生产过程污染物控制北京市重点实验室
作者简介:
基金信息:
DOI:
CLC:TK115;TM621.2
Published:2016
稿件说明:
移动端阅览
LI Yongyi, HAN Yu, CHEN Yuan, et al. A deep waste heat utilization system for utility boilers based on segmented air preheater design[J]. Thermal power generation, 2016, 45(4): 41-47.
DOI:
LI Yongyi, HAN Yu, CHEN Yuan, et al. A deep waste heat utilization system for utility boilers based on segmented air preheater design[J]. Thermal power generation, 2016, 45(4): 41-47.DOI:
A deep waste heat utilization system for utility boilers based on segmented air preheater design
摘要
为了深度挖掘锅炉尾部烟气的余热利用潜力
进一步提高机组效率
降低供电煤耗
低温省煤器技术的常规余热利用系统仅限于加热较低温度凝结水的问题
根据能量梯级利用原则提出了一种基于空气预热器分级串联设计的电站锅炉深度余热利用系统
该系统将空气预热器分3级串联布置
每2级空气预热器之间设置烟水换热器。结合某超超临界1 000 MW燃煤机组
通过对这种新型余热利用系统与常规余热利用系统的热力性能分析、火用分析和经济性分析
对比了2种系统的热经济性。结果表明
对于该机组
采用新型余热利用系统可节约供电标准煤耗为1.94g/(kW·h)
约为常规余热利用系统的1.7倍
且新型余热利用系统的年增加净收益为常规余热利用系统的1.4倍
节能效果与经济效益均显著提高。
Abstract
In order to dig into the potential of flue gas waste heat utilization in tail duct of boilers
further enhance the unit efficiency and reduce the net coal consumption rate
a deep waste heat utilization system of power plant boiler that based on a series design of segmented air preheater was proposed
on the basis of energy cascade utilization principle.This design can improve the deficiency of the conventional waste heat utilization system based on low temperature economizer.The system is divided into three air preheaters arranged in series
and the smoke water heat exchanger is set between two adjacent air preheaters.Combined with a typical 1 000 MW coal-fied unit
thermal efficiency of the novel heat utilization system and conventional system were compared via thermal performance analysis
exergy analysis and technical economic analysis.The results show that
this unit could save standard coal about 1.94g/(kW·h)if adopting new type of waste heat utilization system
which is about 1.7times of that adopting the conventional heat utilization system
at the same time
the economic effect is about 1.4times of the latter.Both the energy saving effect and economic effect of the new waste heat utilization system are very significant.
Optimization on flue gas waste heat recovery scheme in utility boiler
Thermal performance of a new coal-fired power generation system based on organic Rankine cycle
ANALYSIS OF PLATE-TURNOVER PHENOMENON CONCERNING RUDUCTION GEARBOX OF 29-VI(T) 1780 TYPE AIR PREHEATER SURPASSING THE CLUTCH COUPLING AND TECHNICAL RETROFITTING OF THE STARTING-UP CIRCUIT
INFLUENCE OF SCR DENITRIFICATION FACILITY UPON THE BOILER STRUCTURE
ANALYSIS OF EFFECTIVENESS AND ECONOMIC EFFICIENCY FOR ON-LINE WATER FLUSHING OF AIR PREHEATER