Effects of aging on interfacial tension of transformer oil and the countermeasures
|更新时间:2025-09-28
|
Effects of aging on interfacial tension of transformer oil and the countermeasures
Thermal Power GenerationVol. 45, Issue 4, Pages: 116-120(2016)
作者机构:
1. 西安热工研究院有限公司
2. 国网山东省电力公司电力科学研究院
作者简介:
基金信息:
DOI:
CLC:TM407
Published:2016
稿件说明:
移动端阅览
WANG Juan, DU Xiuming, TANG Jinwei, et al. Effects of aging on interfacial tension of transformer oil and the countermeasures[J]. Thermal power generation, 2016, 45(4): 116-120.
DOI:
WANG Juan, DU Xiuming, TANG Jinwei, et al. Effects of aging on interfacial tension of transformer oil and the countermeasures[J]. Thermal power generation, 2016, 45(4): 116-120.DOI:
Effects of aging on interfacial tension of transformer oil and the countermeasures
In order to investigate the changing rules of transformer oil interfacial tension during its aging process and find solutions to treat this unqualified oil
open-cup aging experiments for fresh oil were conducted at different temperatures.The mixing-oil test for unqualified oil with different ratios to fresh oil
and regeneration experiments for the unqualified oil with different amounts of adsorbents were carried out as well.The results show that
the interfacial tension is sensitive to indicate the oxidations content in oil not only in the initial stage of the aging process but also in the later stage
meaning the supervision of interfacial tension should be enhanced during oil monitoring process.When the interfacial tension exceeds the standard value
changing or regenerating the unqualified oil can solve the problem thoroughly.However
due to its high cost and no good at energy conservation and environmental protection