Selection of heat load parameter for 660 MW unit boiler in high-altitude areas
|更新时间:2025-09-28
|
Selection of heat load parameter for 660 MW unit boiler in high-altitude areas
Thermal Power GenerationVol. 45, Issue 4, Pages: 111-115(2016)
作者机构:
1. 神华国能(神东电力)集团公司
2. 青海神华低碳能源投资有限公司
3. 西安热工研究院有限公司
作者简介:
基金信息:
DOI:
CLC:TK221
Published:2016
稿件说明:
移动端阅览
LI Dongpeng, LIU Lijun, LIU Jiali, et al. Selection of heat load parameter for 660 MW unit boiler in high-altitude areas[J]. Thermal power generation, 2016, 45(4): 111-115.
DOI:
LI Dongpeng, LIU Lijun, LIU Jiali, et al. Selection of heat load parameter for 660 MW unit boiler in high-altitude areas[J]. Thermal power generation, 2016, 45(4): 111-115.DOI:
Selection of heat load parameter for 660 MW unit boiler in high-altitude areas
the boiler design and operation experience for 600 MW unit boiler with large capacity and high parameters is empty in the areas with altitude above 2 500 m.In this paper
a simulation combustion test under conditions with high altitude and low air pressure was carried out to obtain the ignition and burnout characteristics of coal samples.Considering the gas expansion characteristics under high altitude and low air pressure condition and the design features of current large scale units
tthe recommended heat load parameters for a 660 MW boiler lying in the area with altitude of 2 900 mare proposed
which can provide references for by large capacity and high parameters boilers' design in high altitude areas.