Optimization on combined operation of low-NOx combustion and SCR denitration system in utility boilers
|更新时间:2025-09-28
|
Optimization on combined operation of low-NOx combustion and SCR denitration system in utility boilers
Thermal Power GenerationVol. 45, Issue 8, Pages: 81-86(2016)
作者机构:
1. 上海明华电力技术工程有限公司
2. 江苏阚山发电有限公司
3. 上海外高桥发电有限责任公司
作者简介:
基金信息:
DOI:
CLC:TM621.2
Published:2016
稿件说明:
移动端阅览
BIAN Shaoshuai, YU Haiyan, YANG Shihua, et al. Optimization on combined operation of low-NOx combustion and SCR denitration system in utility boilers[J]. Thermal power generation, 2016, 45(8): 81-86.
DOI:
BIAN Shaoshuai, YU Haiyan, YANG Shihua, et al. Optimization on combined operation of low-NOx combustion and SCR denitration system in utility boilers[J]. Thermal power generation, 2016, 45(8): 81-86.DOI:
Optimization on combined operation of low-NOx combustion and SCR denitration system in utility boilers
Combing the operation of low-NOxcombustion with SCR denitration system in utility boiler can reduce denitrification operation costs of the whole power unit
which is of great significance in ensuring the safety
environmental protection and economic operation of the units.Considering the effects of oxygen content of flue gas
additional air(AA)quantity
over fire air(OFA)quantity and other factors on the denitration economic performance of the unit
the comprehensive cost model was established for the unit combing low-NOxcombustion with the SCR denitration system.Moreover
low-NOxcombustion adjustment tests of the boiler and denitrification characteristics tests of the SCR denitration system were conducted to obtain operating characteristics and model parameters of the unit.An optimal operation system aiming at minimizing the comprehensive variable costs for the unit denitrification operation was developed
and online operation guidance for denitrification operation of the power unit was realized.The field test results show that
the denitration optimization system gives reasonable operation guidance.After the optimization
in slag in power plant A
the average carbon content reduced by 32%
the boiler efficiency increased by 0.28%
the ammonia consumption increased by 23kg/h
and the total cost dropped by 240yuan/h.In power plant B