Experimental study on ignition delay characteristics of pulverized coal in flat flame entrained flow reactor system
|更新时间:2025-09-28
|
Experimental study on ignition delay characteristics of pulverized coal in flat flame entrained flow reactor system
Thermal Power GenerationVol. 45, Issue 8, Pages: 37-42(2016)
作者机构:
1. 贵州电力试验研究院
2. 华中科技大学能源与动力工程学院
作者简介:
基金信息:
DOI:
CLC:TM621.2
Published:2016
稿件说明:
移动端阅览
LUO Xiaopeng, SHI Jian, CHEN Yuzhong, et al. Experimental study on ignition delay characteristics of pulverized coal in flat flame entrained flow reactor system[J]. Thermal power generation, 2016, 45(8): 37-42.
DOI:
LUO Xiaopeng, SHI Jian, CHEN Yuzhong, et al. Experimental study on ignition delay characteristics of pulverized coal in flat flame entrained flow reactor system[J]. Thermal power generation, 2016, 45(8): 37-42.DOI:
Experimental study on ignition delay characteristics of pulverized coal in flat flame entrained flow reactor system
On a self-built flat flame entrained flow reactor system experimental apparatus
which the temperature can reach 1 750 Kand the heat rate can reach 105 to 106 K/s
experimental study on ignition delay performance of pulverized coal was carried out.Through image acquisition system
the instantaneous image of pulverized coal combustion was obtained
and the variations of the luminous intensity of the pulverized coal were obtained from post processing of the instantaneous images.The results show that
the luminous intensity curves of all kinds of pulverized coal had similar trends
and there was a maximum value of light intensity in each curve.The XINYI(XY)coal had the shortest ignition delay time while the YAXI2(YX2)coal had the longest.This experimental result can provide references for burner design in pulverized coal boilers.