Analysis of sulfates deposition on induced draft fan blade in a coal-fired power plant with ultra-low emission
|更新时间:2025-09-28
|
Analysis of sulfates deposition on induced draft fan blade in a coal-fired power plant with ultra-low emission
Thermal Power GenerationVol. 45, Issue 12, Pages: 9-13(2016)
作者机构:
1. 西安交通大学能源与动力工程学院
2. 神华集团国华(北京)电力研究有限公司
作者简介:
基金信息:
DOI:
CLC:X773;TM621
Published:2016
稿件说明:
移动端阅览
WANG Yibin, TAN Houzhang, XIAO Jiafan, et al. Analysis of sulfates deposition on induced draft fan blade in a coal-fired power plant with ultra-low emission[J]. Thermal power generation, 2016, 45(12): 9-13.
DOI:
WANG Yibin, TAN Houzhang, XIAO Jiafan, et al. Analysis of sulfates deposition on induced draft fan blade in a coal-fired power plant with ultra-low emission[J]. Thermal power generation, 2016, 45(12): 9-13.DOI:
Analysis of sulfates deposition on induced draft fan blade in a coal-fired power plant with ultra-low emission
most power plants apply the selective catalytic reduction(SCR)technology and low temperature electrostatic precipitator to realize ultra-low emission.However
it will result in a much lower flue gas temperature behind the low temperature economizer and sulfates deposition on the induced draft fan blade
which seriously affects the working output of induced draft fan and boiler load.To solve this problem
ash deposits with thickness of 10 mm were collected from the induced draft fan blade in a coalfired power plant with ultra-low emission.The physical and chemical properties of the ash deposits were analyzed by several techniques
such as the element analysis
the mineral matter composition analysis and microstructure analysis.The results show that
the ash samples consisted of calcium sulfate
calcium sulfate dehydrate
aluminium ammonium sulfate(twelve water ammonium aluminum sulfate)
ammonium sulfate and silicon dioxide
the mass fraction of nitrogen
hydrogen and sulfur in ashes was about 22%
after burning the loss mass of unprocessed ash samples was about 60%.The high ammonia concentration escaping from the SCR reactor and the low flue gas temperature behind the low temperature economizer were the main reason for deposition of sulfates on the induced draft fan.So it was suggested that the design of flue gas temperature at the low temperature economizer outlet need further study considering different kinds of coal