Failure analysis of flange used for urea hydrolysis equipment
|更新时间:2025-09-28
|
Failure analysis of flange used for urea hydrolysis equipment
Thermal Power GenerationVol. 45, Issue 6, Pages: 111-115(2016)
作者机构:
西安热工研究院有限公司
作者简介:
基金信息:
DOI:
CLC:TQ113.2;TG142.71
Published:2016
稿件说明:
移动端阅览
HUANG Jinyang, YANG Zheng, LU Jintao, et al. Failure analysis of flange used for urea hydrolysis equipment[J]. Thermal power generation, 2016, 45(6): 111-115.
DOI:
HUANG Jinyang, YANG Zheng, LU Jintao, et al. Failure analysis of flange used for urea hydrolysis equipment[J]. Thermal power generation, 2016, 45(6): 111-115.DOI:
Failure analysis of flange used for urea hydrolysis equipment
scanning electron microscope(SEM)and X-ray diffraction(XRD)
the failure behavior of a seal flange made by TP304 stainless steel used at outlet of the urea hydrolysis equipment for flue gas denitrification was analyzed.The results show that
the failure of the flange plate was mainly caused by the continuous pitting corrosion and dissolved corrosion in high temperature and pressure urea corrosive medium.The interface between the corrosive medium and flange plate was serrated and the corrosion products were mainly Fe and Cr oxides.Loose structure and a large number of holes and cracks appeared in the corrosion products.The TP304 austenitic stainless steel is unsuitable for the seal flange material for urea hydrolysis equipment in flue gas denitrificaiton.