Working fluid selection for organic Rankine cycle in low temperature waste heat system
|更新时间:2025-09-28
|
Working fluid selection for organic Rankine cycle in low temperature waste heat system
Thermal Power GenerationVol. 45, Issue 8, Pages: 20-25(2016)
作者机构:
华北电力大学电站设备状态监测与控制教育部重点实验室
作者简介:
基金信息:
DOI:
CLC:TK115;TK124
Published:2016
稿件说明:
移动端阅览
LI Hengfan, ZHAO Yujin, HAN Zhonghe. Working fluid selection for organic Rankine cycle in low temperature waste heat system[J]. Thermal power generation, 2016, 45(8): 20-25.
DOI:
LI Hengfan, ZHAO Yujin, HAN Zhonghe. Working fluid selection for organic Rankine cycle in low temperature waste heat system[J]. Thermal power generation, 2016, 45(8): 20-25.DOI:
Working fluid selection for organic Rankine cycle in low temperature waste heat system
In order to study the heat transfer characteristics of the low-temperature organic Rankine cycle(ORC)and obtain the optimum refrigerant mixtures
this paper select R245fa+cyclohexane as the component of mixed fluid to establish numerical model for the evaporator.By analyzing the optimal outlet temperature and exergy loss ratio of the flue gas under conditions with different mixed fluids
the optimal gas temperature at different compositions and the optimal performance refrigerants were ascertained.The results show that
the mixture with different compositions has different optimum gas temperature.When the mass ratio of R245 fa to cyclohexane in the mixed fluid equaled 0.56∶0.44
the fluid's exergy loss was the minimum and the heat transfer process was the closest to the ideal heat transfer.