Experimental research on heat charging and discharging performance of heat pipe phase change energy storage system
|更新时间:2025-09-28
|
Experimental research on heat charging and discharging performance of heat pipe phase change energy storage system
Thermal Power GenerationVol. 45, Issue 11, Pages: 48-53(2016)
作者机构:
上海海事大学商船学院
作者简介:
基金信息:
DOI:
CLC:TK02;TK172.4
Published:2016
稿件说明:
移动端阅览
MAO Fa, ZHANG Xuelai, DING Lei, et al. Experimental research on heat charging and discharging performance of heat pipe phase change energy storage system[J]. Thermal power generation, 2016, 45(11): 48-53.
DOI:
MAO Fa, ZHANG Xuelai, DING Lei, et al. Experimental research on heat charging and discharging performance of heat pipe phase change energy storage system[J]. Thermal power generation, 2016, 45(11): 48-53.DOI:
Experimental research on heat charging and discharging performance of heat pipe phase change energy storage system
By choosing Ba(OH)2·8H2O as phase change heat storage material and taking heat pipe as the heat transfer element
a heat pipe phase change energy storage system was designed.The heat storage performance of the system was explored by changing the experimental conditions.The results show that:The thermal homogeneity of the heat pipe in the regenerator is good.With an increase in the heating fluid temperature and flow rate
the temperature of the phase change material increases and the phase transformation time decreases.With an decrease in inlet temperature and inlet flow
the temperature difference of inlet and outlet fluid increases.When the inlet temperature decreases and the inlet flow increases
the heat storage efficiency decreases.When the inlet temperature is 18 ℃
the heat storage efficiency reaches up to 89.2%and the highest outlet temperature is 49.5 ℃.When the inlet flow is 0.008 m3/h
the heat storage efficiency is as high as 87.5% and the highest outlet temperature is 47.4 ℃.