Numerical simulation and optimization of SCR denitration system based on component transport model
|更新时间:2025-09-28
|
Numerical simulation and optimization of SCR denitration system based on component transport model
Thermal Power GenerationVol. 45, Issue 11, Pages: 106-113(2016)
作者机构:
江苏科技大学冶金与材料工程学院
作者简介:
基金信息:
DOI:
CLC:X773
Published:2016
稿件说明:
移动端阅览
JIANG Xiaoming, NIE Yuhong, JIN Yunxue, et al. Numerical simulation and optimization of SCR denitration system based on component transport model[J]. Thermal power generation, 2016, 45(11): 106-113.
DOI:
JIANG Xiaoming, NIE Yuhong, JIN Yunxue, et al. Numerical simulation and optimization of SCR denitration system based on component transport model[J]. Thermal power generation, 2016, 45(11): 106-113.DOI:
Numerical simulation and optimization of SCR denitration system based on component transport model
摘要
采用计算流体力学软件对某600 MW燃煤机组烟气脱硝系统的烟气流场和氨浓度场进行仿真模拟
将不同组分烟气和氨混合物与湍流流动方程耦合求解
得到了系统内的烟气流动和组分分布状况;并根据模拟结果对烟道进行优化。结果表明:在BMCR工况下
3个烟道直角转角处加入渐缩型圆弧导流板
首层催化剂前加入整流格栅
使脱硝装置流速不均匀系数从47.42%降至12.18%
但氨浓度均匀性未满足要求;当整流格栅倾斜角为30°
在烟气脱硝反应器入口拐角处等间距布置3片1/4圆弧导板
烟气流速分布不均匀系数和氨浓度分布不均匀系数分别为8.27%和9.53%
满足技术要求;此外
该方案在不同运行工况下均满足技术要求
因而适用于机组变负荷运行。
Abstract
The CFD software was adopted to simulate and optimize the flow field and NH3 concentration field for a subcritical 600 MW coal-fired unit.The gas mixture component and the turbulent flow equation were coupled to solve
and the flow field and component concentration distribution of the flue gas were ascertained.The results show that
under the BMCR condition
adding converging circular guiding plate at the quarter turn of three flue ducts and installing cascade grid in front of the first layer of catalyst
can decrease the non-uniformity of velocity from 47.42%to 12.18%
but the that of the NH3 concentration is not satisfied.When the inclination angle of the cascade grid reaches 30°and 3pieces of 1/4circular guiding plates is arranged in the reactor inlet corner spacing
the non-uniformity of velocity and mole fraction of NH3are8.27% and 9.53%
respectively
which satisfies the technical requirements.The scheme is suitable for varying load operation of thermal power unit.