Flow field in the upstream circular primary air duct of medium speed mills:numerical simulation and optimization design
|更新时间:2025-09-28
|
Flow field in the upstream circular primary air duct of medium speed mills:numerical simulation and optimization design
Thermal Power GenerationVol. 45, Issue 11, Pages: 99-105(2016)
作者机构:
西安热工研究院有限公司
作者简介:
基金信息:
DOI:
CLC:TM621
Published:2016
稿件说明:
移动端阅览
MEI Zhenfeng, CHEN Min, XU Miaofeng, et al. Flow field in the upstream circular primary air duct of medium speed mills:numerical simulation and optimization design[J]. Thermal power generation, 2016, 45(11): 99-105.
DOI:
MEI Zhenfeng, CHEN Min, XU Miaofeng, et al. Flow field in the upstream circular primary air duct of medium speed mills:numerical simulation and optimization design[J]. Thermal power generation, 2016, 45(11): 99-105.DOI:
Flow field in the upstream circular primary air duct of medium speed mills:numerical simulation and optimization design
In upstream round ducts of medium speed mills in a 1 000 MW UNIT coal-fired boiler
the measurements of the flow rate of primary air are usually not accurate and thus automatic control systems cannot work.To solve this problem
a cold-hot air flow mixing and equalizing device which is suitable for the circular primary air duct in front of the coal mill is designed
by numerical simulations.Moreover
the performance of this device is verified through the pilot-scale cold state experiment of physical models.The numerical simulation and cold state physical model test results indicate that
the combined layout of the uniform distribution device of cold air
deflector
grilling and perforated plate can solve the torsion problem of flow stream in the circular primary air duct in front of the medium speed coal mill
make the incoming gas velocity's direction(in measurement section of the primary air)be vertical to the detecting device.The combination layout makes the relative standard deviation(RSD)of the air velocity and temperature at the recommend traverse drop to 6% and 2%
respectively.Simultaneously
the corresponding increases of the pressure losses of cold and hot primary air are less than 400 Pa.The uniform distribution of the cold primary air at the confluence of cold and hot air is realized.