Uniformity improvement for bed temperature of a 300MW unit CFB boiler
|更新时间:2025-09-28
|
Uniformity improvement for bed temperature of a 300MW unit CFB boiler
Thermal Power GenerationVol. 45, Issue 11, Pages: 68-74(2016)
作者机构:
1. 中国华能集团清洁能源技术研究院有限公司
2. 山西国际能源集团有限公司
3. 神华神东电力有限责任公司新疆米东热电厂
作者简介:
基金信息:
DOI:
CLC:TK229.66
Published:2016
稿件说明:
移动端阅览
HUANG Zhong, GUO Taixing, LIANG Jinlin, et al. Uniformity improvement for bed temperature of a 300MW unit CFB boiler[J]. Thermal power generation, 2016, 45(11): 68-74.
DOI:
HUANG Zhong, GUO Taixing, LIANG Jinlin, et al. Uniformity improvement for bed temperature of a 300MW unit CFB boiler[J]. Thermal power generation, 2016, 45(11): 68-74.DOI:
Uniformity improvement for bed temperature of a 300MW unit CFB boiler
several problems occur in large number of 300 MW unit CFB boilers
such as large bed temperature deviations
existence of local high temperature points and relatively high original emission concentration of SO2 and NOx
which brings difficulties in energy saving
cost reducing and ultra-low emission of the CFB boilers.Analysis shows that
the deviations of separator flow and efficiency result in deviations between the circulation volume and the material concentration in the circulation loop
thus bring the temperature deviation at both sides and middle part of the bed.The temperature deviation can be avoided by retrofitting the separator inlet gas flue and cyclone vortex
which would contribute to a more even coal supply.After transformation
the average bed temperature decreased by more than 35℃
and the consumptions of the desulfurizer and denitration urea are reduced by 40% and 20%