Numerical optimization of tertiary-air declination angle for a 350MW W-shaped supercritical boiler with multi-injection and staging combustion
|更新时间:2025-09-28
|
Numerical optimization of tertiary-air declination angle for a 350MW W-shaped supercritical boiler with multi-injection and staging combustion
Thermal Power GenerationVol. 46, Issue 1, Pages: 30-35(2017)
作者机构:
1. 哈尔滨工业大学能源科学与工程学院
2. 宁波大学海运学院
作者简介:
基金信息:
DOI:
CLC:TM621.2
Published:2017
稿件说明:
移动端阅览
ZHU Qunyi, ZENG Lingyan, KUANG Min, et al. Numerical optimization of tertiary-air declination angle for a 350MW W-shaped supercritical boiler with multi-injection and staging combustion[J]. Thermal power generation, 2017, 46(1): 30-35.
DOI:
ZHU Qunyi, ZENG Lingyan, KUANG Min, et al. Numerical optimization of tertiary-air declination angle for a 350MW W-shaped supercritical boiler with multi-injection and staging combustion[J]. Thermal power generation, 2017, 46(1): 30-35.DOI:
Numerical optimization of tertiary-air declination angle for a 350MW W-shaped supercritical boiler with multi-injection and staging combustion
For a newly built supercritical 350 MW unit with down-fired boiler applying multi-injection staging combustion technology
the fluid flow and combustion characteristics inside the furnace were numerically simulated
under conditions with the tertiary air declination angle of 0°
10°
20°
30°.The results show that
with the tertiary air declination angle of 0°and 10°
a deflected flow field with low furnace room utilization efficiency was observed
accompanied by high levels of gas temperature and NOx emissions at the furnace outlet.As the tertiary air declination angle increased to 20°
the flow filed turned into a relatively symmetrical pattern with great flame penetration depth
and the aforementioned high NOxemission at the furnace outlet decreased apparently to acceptable levels.However
excessively increasing the tertiary air declination angle to 30°resulted in an excessively large downward flame penetration depth
with the downward coal/air flow washing over the hopper wall and high gas temperatures in the hopper zone.Comprehensively considering the formation of symmetric combustion with low NOxemission and gas temperature at the furnace outlet
the optimal tertiary-air declination angle should be 20°.
COMPARISON AND ANALYTICAL STUDY ON NOx EMISSION FROM VARIOUS W-SHAPED FLAME BOILERS IN SERVICE
STUDY ON DIFFICULTY IN ENHANCING OXYGEN AMOUNT UNDER OPERATION AT HIGH LOAD OF FW TYPE W-SHAPED FLAME BOILER
STUDY ON CORRELATION BETWEEN AIR FLOW RATE AT FURNACE INLET AND FLUE GAS TEMPERATURE AT FURNACE OUTLET
STUDY ON COMBINED APPLICATION OF LOW NOx COMBUSTION AND SNCR IN WSHAPED FLAME BOILER
ANALYSIS OF OVERTEMPERATURE PROBLEM OCCURRED ON PIPE WALL OF HIGH-TEPERATURE HEATING SURFACE FOR BOILERS IN ZHUHAI POWER PLANT AND SOLVING SCHEME THEREOF
Related Author
BAI Shao-lin (Xi’an Thermal Power Research Institute Co Ltd
LIU Hong-gang
XU Dang-qi2 (1.Yangcheng Power Generation Co Ltd
LIU Hong-gang2
YANG Zhong-can2
WEI Tong-sheng2
JIN Xin1
DUAN Bao-lin1
Related Institution
Xi'an Thermal Power Research Institute Co., Ltd
Yangcheng International Power Generation Co., Ltd
College of Energy and Power Engineering, North China Electric Power University
Guangqian Electric Power Co., Ltd
Yantai Longyuan Electric Power Technology Co., Ltd