Experimental study on combustion and emission characteristics of a supercritical 600 MW unit CFB boiler firing different coals
|更新时间:2025-09-28
|
Experimental study on combustion and emission characteristics of a supercritical 600 MW unit CFB boiler firing different coals
Thermal Power GenerationVol. 46, Issue 4, Pages: 46-51(2017)
作者机构:
1. 中国华能集团清洁能源技术研究院有限公司
2. 四川白马循环流化床示范电站有限责任公司
作者简介:
基金信息:
DOI:
CLC:TM621.2
Published:2017
稿件说明:
移动端阅览
JIN Senwang, GAO Hongpei, SUN Xianbin, et al. Experimental study on combustion and emission characteristics of a supercritical 600 MW unit CFB boiler firing different coals[J]. Thermal power generation, 2017, 46(4): 46-51.
DOI:
JIN Senwang, GAO Hongpei, SUN Xianbin, et al. Experimental study on combustion and emission characteristics of a supercritical 600 MW unit CFB boiler firing different coals[J]. Thermal power generation, 2017, 46(4): 46-51.DOI:
Experimental study on combustion and emission characteristics of a supercritical 600 MW unit CFB boiler firing different coals
emission characteristics and adaptability of a supercritical 600 MW unit CFB boiler firing different coals were studied. The test results show that
the main equipment and auxiliary system of the boiler has well adaptability to the coal type. When burning different kinds of coals
the boiler has relatively high combustion efficiency. The combustion efficiency reached the highest 97.94% when firing pure Shenhua coal and the lowest 94.76% when firing the pure design coal
it is within the range when firing blended coals. The boiler applies the dry desulfurization process
with the highest desulfurization efficiency of 98.2% and the minimum of 94.8%. Under all test conditions
the SO_2 emissions were lower than 300 mg/m~3
and the NOx emissions were lower than 200 mg/m~3
which meets the requirements of environmental emission limits at the present stage. The ignition test shows the ignition temperature of the design coal is 430 ℃