Prediction model for flue gas wet desulfurization efficiency based on partial least squares support vector machine
|更新时间:2025-09-28
|
Prediction model for flue gas wet desulfurization efficiency based on partial least squares support vector machine
Thermal Power GenerationVol. 46, Issue 4, Pages: 81-87(2017)
作者机构:
1. 浙江理工大学信息学院
2. 聚光科技(杭州)股份有限公司
作者简介:
基金信息:
DOI:
CLC:X773
Published:2017
稿件说明:
移动端阅览
CUI Shiwen, TIE Zhixin, DING Chengfu, et al. Prediction model for flue gas wet desulfurization efficiency based on partial least squares support vector machine[J]. Thermal power generation, 2017, 46(4): 81-87.
DOI:
CUI Shiwen, TIE Zhixin, DING Chengfu, et al. Prediction model for flue gas wet desulfurization efficiency based on partial least squares support vector machine[J]. Thermal power generation, 2017, 46(4): 81-87.DOI:
Prediction model for flue gas wet desulfurization efficiency based on partial least squares support vector machine
摘要
为了能够更好地反映电厂湿法脱硫中的过程参数与脱硫效率之间的关系
本文利用偏最小二乘回归法(PLS)对影响烟气湿法脱硫效率的过程因素进行分析
提取出对湿法脱硫效率影响较大的因素作为主成分
将提取的主成分采用支持向量机(SVM)进行预测
降低了SVM的输入维数
建立了基于偏最小二乘支持向量机(PLS-SVM)的烟气湿法脱硫效率预测模型
并选取某机组石灰石-石膏湿法脱硫设施运行监控数据进行模型的训练和预测。预测分析结果显示
PLS-SVM的预测数据最大绝对误差小于0.65%
平均绝对误差在0.3%左右
说明该模型的预测效果较好
与SVM预测模型相比
提高了预测效率和精度。
Abstract
In order to better reflect the relationship between the wet flue gas desulfurization process parameters and the desulfurization efficiency
the partial least squares regression(PLS) method was applied to analyze the process factors affecting the flue gas desulfurization efficiency
then the factors affecting the desulfurization efficiency greatly were considered as the principal components and were extracted for prediction using the support vector machine(SVM). Thus
on the basis of the partial least squares support vector machine(PLS-SVM)
a prediction model for wet flue gas desulfurization efficiency was established
which can reduce the input dimensions of the SVM. Moreover
the data of the operation monitoring system of the limestone gypsum wet desulphurization facility were selected to carry out the training and prediction for the model. The prediction results show that
the maximum absolute prediction error of the PLS-SVM model is below 0.65%
and the average absolute error is about 0.3%
indicating the above model can well predict the desulfurization efficiency
and its prediction efficiency and accuracy is higher than that of the SVM model. In order to better reflect the relationship between the wet flue gas desulfurization process parameters and the desulfurization efficiency
the partial least squares regression(PLS) method was applied to analyze the process factors affecting the flue gas desulfurization efficiency
then the factors affecting the desulfurization efficiency greatly were considered as the principal components and were extracted for prediction using the support vector machine(SVM). Thus
on the basis of the partial least squares support vector machine(PLS-SVM)
a prediction model for wet flue gas desulfurization efficiency was established
which can reduce the input dimensions of the SVM. Moreover
the data of the operation monitoring system of the limestone gypsum wet desulphurization facility were selected to carry out the training and prediction for the model. The prediction results show that
the maximum absolute prediction error of the PLS-SVM model is below 0.65%
and the average absolute error is about 0.3%
indicating the above model can well predict the desulfurization efficiency
and its prediction efficiency and accuracy is higher than that of the SVM model.