Application of non-symmetrical high-speed closing-to-wall air system to a Russian-made 530MW unit coal fired boiler
|更新时间:2025-09-28
|
Application of non-symmetrical high-speed closing-to-wall air system to a Russian-made 530MW unit coal fired boiler
Thermal Power GenerationVol. 46, Issue 3, Pages: 87-92(2017)
作者机构:
1. 天津国华盘山发电有限责任公司
2. 西安热工研究院有限公司
作者简介:
基金信息:
DOI:
CLC:TM621.2
Published:2017
稿件说明:
移动端阅览
LIANG Xuebin, SUN Jun, MENG Yi, et al. Application of non-symmetrical high-speed closing-to-wall air system to a Russian-made 530MW unit coal fired boiler[J]. Thermal power generation, 2017, 46(3): 87-92.
DOI:
LIANG Xuebin, SUN Jun, MENG Yi, et al. Application of non-symmetrical high-speed closing-to-wall air system to a Russian-made 530MW unit coal fired boiler[J]. Thermal power generation, 2017, 46(3): 87-92.DOI:
Application of non-symmetrical high-speed closing-to-wall air system to a Russian-made 530MW unit coal fired boiler
摘要
为防治530MW俄制机组燃煤锅炉炉膛水冷壁高温腐蚀
在该锅炉上加装了非对称高速贴壁风系统
并进行了燃烧调整试验。结果表明
贴壁风改造后
锅炉水冷壁近壁气氛显著改善
炉膛水冷壁高温腐蚀得到有效防治
SCR反应器入口NO_x质量浓度可控制在150~170mg/m~3
锅炉热效率提高0.2%
锅炉运行安全性、经济性和环保性显著提高
可为墙式对冲燃烧电站锅炉防治水冷壁高温腐蚀和NO_x排放控制提供示范作用。
Abstract
To prevent high temperature corrosion of water walls in boiler furnace and reduce NOxemission from a Russian-made 530 MW unit coal fired boiler
the non-symmetrical high speed closing-to-wall air system was designed and applied.Moreover
the corresponding combustion adjusting tests were carried out.The results show that
after the technical transformation and the combustion adjusting tests
the atmosphere close to the water wall was improved obviously
the high temperature corrosion on the water wall was dramatically prevented
the NOxconcentration at the SCR reactor inlet can be kept between 150mg/m~3 and 170mg/m~3
and the boiler efficiency can be increased by 0.2%.The operating security
economy and environmental protection performance of the boiler improved obviously.The results have a demonstration function for NOxemission control and prevention of high temperature corrosion on water walls of the wall type opposed firing boilers.