Thermal-economic analysis for scheme of steam turbine generator placement in high and low platform separately
|更新时间:2025-09-28
|
Thermal-economic analysis for scheme of steam turbine generator placement in high and low platform separately
Thermal Power GenerationVol. 46, Issue 7, Pages: 1-4(2017)
作者机构:
西安西热节能技术有限公司
作者简介:
基金信息:
DOI:
CLC:TM621
Published:2017
稿件说明:
移动端阅览
FU Yiwei, XIE Tian, QU Jie. Thermal-economic analysis for scheme of steam turbine generator placement in high and low platform separately[J]. Thermal power generation, 2017, 46(7): 1-4.
DOI:
FU Yiwei, XIE Tian, QU Jie. Thermal-economic analysis for scheme of steam turbine generator placement in high and low platform separately[J]. Thermal power generation, 2017, 46(7): 1-4.DOI:
Thermal-economic analysis for scheme of steam turbine generator placement in high and low platform separately
In order to analyze thermal economy of thermal system with steam turbine generator placement in high and low platform separately(new replacement scheme)
the resistance change of the thermal system before and after the new scheme is employed was calculated based on fluid mechanics
and the detailed thermodynamic model for domestic typical 1 000 MW unit with single-and double-reheat cycle was established
on the basis of the EBSILON? software. Moreover
the thermal efficiency of the thermal system using regular scheme and the new scheme was compared. The result shows that
in the new scheme
the heat rate drops caused by resistance drop in the main steam pipe and reheat steam pipe are in the same order of magnitude. For reheat units
because the system resistance decreases after the new replacement scheme is used
the coal consumption rate of power generation reduces by 0.5 g/(kW·h). For double-reheat units
the coal consumption rate of power generation reduces b y1 g/(kW·h)